TURN OLD WINDOW AC PARTS INTO A MACHINE THAT MAKES LIQUID NITROGEN

A garage-built cryocooler that makes liquid nitrogen at -196 °C from salvaged window air conditioner compressors and hardware store copper tubing.

by Hyperspace Pirate

ScienceWorkshop

difficulty
●●●●●
time
a year-plus
license
license not specified
repo
repo
1
Jump to section

COMPAREE VERDICT

This is a cryocooler that makes real liquid nitrogen in a garage, built from compressors salvaged from old window AC units and copper tubing from the hardware store. It uses a mixed-gas Joule-Thomson cycle: a blend of propane, ethylene, methane, argon and nitrogen is compressed to about 28 bar and expands through a long counterflow heat exchanger, getting colder each pass. A separate vapor compression stage pre-cools the gas to about -25 to -30 °C. The cold end reaches -177 °C, enough to liquefy nitrogen gas fed in at about 450 psi. It poured out 108 g of liquid nitrogen in one run, reading -194 to -196 °C on a thermocouple, and levitated a magnet over a YBCO superconductor. It draws about 1,400 W and makes around 130 cc per hour — which works out at 1.29 dollars per litre in electricity versus 5 dollars from a gas supplier, and about 50,800 dollars for a lab liquid nitrogen generator like the TRITON2S. The catch: it took a year and a half, there are no build files, you are working from video only, the gas mix is flammable and under high pressure, an earlier tank ruptured, and you still need bottled nitrogen gas to feed it. This is not a weekend build and the single most likely thing to go wrong is a high-pressure leak or a bad braze joint failing under thermal cycling.

GOOD TO KNOW

  • —There is no repository for this build — everything is in a 14-minute YouTube video.
  • —No CAD files, no BOM, no parts list with suppliers, no wiring diagrams.
  • —The video shows what was built and how it works, but you are reverse-engineering from footage.
  • —No licence is stated — the video is demonstration, not instructions.
  • —The gas mixture (propane, ethylene, methane, argon, nitrogen) is flammable and stored at 28 bar; the nitrogen feed is from a commercial tank.
  • —An earlier liquid methane tank ruptured at a braze joint.

Parts to buy

9 items

From our check of the build. Exact quantities and part numbers are in the creator’s BOM.

  • Compressors from scrapped window AC unitsFind
  • Copper tubingFind
  • Motorized valvesFind
  • ThermocouplesFind
  • Insulation (rubber foam and fiberglass)Find
  • Foam boxFind
  • Gas cylinders (propane, ethylene, methane, argon, nitrogen)Find
  • Fittings and gauges for high-pressure gasFind
  • Electronic expansion valveFind

Can I build this?

Printnothing required
Buycompressors from scrapped window AC units (one 12,000 BTU, two 5,000 BTU mentioned), copper tubing, motorized valves, thermocouples, insulation (rubber foam and fiberglass), a foam box, gas cylinders (propane, ethylene, methane, argon, nitrogen), fittings and gauges for high-pressure gas, electronic expansion valve
Toolsbrazing equipment, pressure testing gear, vacuum pump for refrigeration, multimeter, thermocouple reader, hand tools, safety equipment for handling flammable gases and cryogenic liquids
SkillsAdvanced: refrigeration system design, high-pressure gas handling, brazing copper tubing, thermodynamics (Joule-Thomson cycle), working safely with flammable gases and cryogenic temperatures. This is not a first project.
Timea year and a half reported by the builder
Cost$$$, dominated by compressors (if bought new), gas cylinders, valves and fittings, and the recurring cost of feed gases
SafetyReal hazards: high-pressure flammable gas mixture (propane, ethylene, methane) at 28 bar; earlier liquid methane tank ruptured at a braze joint; liquid nitrogen causes cold burns on contact; risk of asphyxiation in poorly ventilated spaces if nitrogen displaces air; electric shock from mains-powered compressors.

This build involves mains voltage — for adults comfortable with electrical work only.

Build at your own risk. Projects involve tools, electronics and sometimes mains voltage — follow the creator’s safety notes.

Videos

Making Liquid Nitrogen with my Homemade Cryocooler14:04

15 July 2024, 362k views. Shows the build, explains the mixed-gas Joule-Thomson cycle, demonstrates the system running and pouring liquid nitrogen, levitating a magnet over a superconductor, and freezing an orange. No step-by-step build instructions.

More builds like this

All projects

Gallery

Start here

Navigation into the creator’s own docs — we don’t rewrite the guide, we route you to the source.

  1. 1.Watch the full 14-minute video (This is your only documentation — take notes on the compressor layout, tubing runs, insulation and valve placement.)
  2. 2.Source compressors from scrap or HVAC suppliers(The builder used one 12,000 BTU and two 5,000 BTU window AC compressors.)
  3. 3.Learn refrigeration brazing if you have not done it before(A bad braze joint under thermal cycling is the failure mode that caused an earlier tank to rupture.)

KNOWN ISSUES

  • There are no build files, BOM or wiring diagrams — you are reverse-engineering from a 14-minute video and will miss details.
  • The gas mixture (propane, ethylene, methane, argon, nitrogen) is flammable and stored at 28 bar; a leak near an ignition source is a fire hazard.
  • An earlier liquid methane tank ruptured at a braze joint — thermal cycling stresses fittings and any weak joint can fail catastrophically.
  • You still need a commercial nitrogen gas cylinder to feed the system — this is not making nitrogen from air.
  • Liquid nitrogen causes cold burns on contact and can displace air in a closed space, causing asphyxiation.
  • The system took the builder a year and a half — this is not a quick project and the learning curve on cryogenic refrigeration is steep.

Does this make nitrogen from air?

No. It liquefies nitrogen gas from a bought tank, pumped into the cold tank at about 450 psi. He plans to show making nitrogen from air in a future video.

What is the energy cost compared to buying liquid nitrogen?

The builder reports about 1.29 dollars per litre in electricity versus 5 dollars per litre from a gas supplier, drawing 1,400 W to make around 130 cc per hour.

Is the gas mixture safe?

No — it contains propane, ethylene and methane, all flammable, compressed to 28 bar. A leak is a fire and explosion hazard.

Can I skip the pre-cooling stage?

He says the system works without it, but the pre-cooling stage gives it a tremendous boost, so he uses it.

Community builds

No community builds yet — be the first, we feature the best ones.

Discussion1

FROM THE COMPAREE TEAM

It makes 130 cc per hour at a claimed electricity cost of 1.29 dollars per litre, and a lab machine that does 8 litres per day lists at about 50,800 dollars. If you were building this, would you commit a year to it for the cost savings, or is the nitrogen cylinder the real limit?

CompareeTEAM1mo ago

We verified the video and the numbers in it. There is no repository, no project page, no build files — the video is the entire source. The builder states plainly that an earlier liquid methane tank ruptured at a braze joint, and the gas mix is flammable (propane, ethylene, methane) at 28 bar. This is not a beginner project and the lack of documentation means you are on your own for everything the video does not show. If you have never brazed copper tubing or worked with high-pressure refrigeration, start somewhere smaller.

Hyperspace Pirate

Hyperspace Pirate built this cryocooler over a year and a half, salvaging compressors from old window air conditioners and designing a mixed-gas Joule-Thomson refrigeration cycle to reach liquid nitrogen temperatures in a garage.

Star the project on GitHub

DISCLAIMER

  • Comparee is not the author of the projects featured here. All rights to each project belong to its creator — every page links to the original source, and we never host creators’ files.
  • Information is provided without warranty and may become outdated as projects evolve. Prices are indicative bands only — always check the creator’s parts list for current costs.
  • Building and operating any project is at your own responsibility. Protective equipment, safe workshop practice and compliance with local regulations are the builder’s responsibility.